-
- How does a module generally look like?
- How does LabCollector interface look like?
- How to set up storage in LabCollector?
- How to start with Antibodies module?
- How to start with Chemical structures module?
- How to start with Document module?
- How to start with Electronic Lab Notebook (ELN)?
- How to start with Equipment module?
- How to start with Plasmids module?
- How to start with Primers module?
- How to start with Reagent & Supplies module?
- How to start with Sample module?
- How to start with Sequences module?
- How to start with Strains & Cells module?
- What are fields in LabCollector?
- What are records in LabCollector & how to create them?
- How to install an Add-on?
- Show all articles ( 2 ) Collapse Articles
-
-
- Articles coming soon
-
- How do I create alerts for chemical and equipment?
- How do I create alerts with lots? (v6.0)
- How do I manage vendors and sellers?
- How do I print risk and safety data information?
- How to do lot disposal
- Import and manage your Reagent & Supplies V5.3 and above
- Manage storage for Reagent & Supplies module
- Manage storage for Reagent & Supplies module (v6.0)
- Manage your reagent lots
- Manage your reagent lots (v6.0)
- Reagent & supplies preferences
- Risk codes
- How to start with Reagent & Supplies module?
-
- Articles coming soon
-
- Articles coming soon
-
- How do I create alerts for chemical and equipment?
- How to activate and set different types of Equipment alerts? (v5.4 and below)
- How to activate and set different types of Equipment alerts? (v6.0)
- How to add a new category and record in equipment module? (v5.4 and below)
- How to add a new category and record in equipment module? (v6.0)
- How to add control chart for calibration maintenance of equipment?
- How to add maintenance and activate alert for a equipment (v6.0)
- How to add/edit maintenance for equipment (v5.4 and below)
- How to add/edit maintenance for equipment (v6.0)
- How to export equipment maintenance report?
- What are the options in "display maintenance" section of equipment. (v5.4 and below)
- What are the options in "display maintenance" section of equipment. (v6.0)
-
- Articles coming soon
-
-
-
- How to manage case records (patients, animals...) in LSM?
- How to re-order/re-arrange job & sample custom fields in LSM?
- How to manage range in LSM?
- How to restart a job in LSM?
- I’m able to add a new job with no problems but when I try to start it I can’t do it. The following error appears: Error loading XML document: data/bl/bl-job.php. What’s the problem?
- How to send samples from LabCollector to a LSM job
- 1st step: Create users and requesters
- How to link a custom module to LSM?
-
- Dynamic fields in LSM for result/invoice/CoC/batch report templates?
- How to generate Reports in LSM?
- 5th step: Result and invoice template
- How to generate Invoices report template in LSM?
- Error loading big reports in LabCollector
- Error loading big reports in LSM
- How to use text editor to create a report template in LSM?
- How to create a Chain Of Custody (CoC) report and use it LSM & LSMRemote?
- Correction/Amendement actions in LSM report
- How to create a processing report in LSM?
-
- How to configure new fields, submit a job in LSMRemote & view it in LSM?
- LSMRemote (v6.0) registration, login and other options
- LSMRemote configurable options (v4.0)
- LSMRemote installation steps & Integration into the website ? (v4.0)
- How to create a token for report access for patient/client using LSMRemote?
- Patient pre-registration configuration and LSMRemote portal connection
- How to enable the soap.dll extension using php file or LabCollector Server Manager (Windows)?
-
- Articles coming soon
-
-
-
- ELN - Zoho Spreadsheet Help Guide
- Graph in Flat spreadsheet
- How to change the language of ZOHO excel in ELN?
- How to replicate/import your excel in ELN?
- How to use spreadsheets?
- What is Flat & Zoho Spreadsheet Editor & how to enable it?
- How to use Flat spreadsheet & formulas in it?
- How to make graph in Flat Spreadsheet?
- What can be copy pasted from excel into Flat spreadsheet?
-
- Articles coming soon
-
- Articles coming soon
-
- Articles coming soon
-
- How to add samples created in sample receiving into Workflow add-on?
- How to connect and send samples from 'sample receiving' to do tests in 'LSM'?
- How to create & process a package in Sample receiving add-on?
- How to process plates in sample receiving add-on?
- How to view samples created in sample receiving add-on into a module?
- Sample-receiving add-on : Project configuration settings
- How to perform pooling in sample receiving add on?
-
- Articles coming soon
-
-
- Can I see/list all records in a module?
- Can I use LabCollector on a single computer? Can I install it on a web server?
- Client area tutorial
- Client area tutorial - NEW!
- Do I need to purchase all modules? Can I use only the primers module?
- How do I install LabCollector? Where can I find the install.exe file?
- How do I obtain my license?
- How do I print records?
- How do I search in LabCollector
- How does the remotely hosted version work?
- How to add panels to LabColletor v6.0?
- How to create and set alerts for tubes? (v6.0)
- How to create tubes with storage and mark their usage? (v6.0)
- Icons meaning (EN/FR)
- Icons meaning (EN/FR) V.6.0
- If I purchase ONE license, do I need to purchase additional licenses for other computers in my lab network?
- LabCollector support
- System Requirements - Hosted options (FR/ENG)
- What are the FDA requirements for software to comply with GxP guidelines?
- What is LabCollector?
- Label network printers and roll types
- Show all articles ( 6 ) Collapse Articles
-
-
- Can I add a custom module to fit my specific needs?
- Custom field types
- Custom field: Field category option version 5.2x
- Custom fields: Tab Analysis option
- How do I customize record options?
- How do I use a Read-only field?
- How do you create a custom field?
- How do you create a custom field? For version 5.2 onwards
- What can I do with the default fields?
-
- How do I format the date value as yyyy-mm-dd or yy-mm-dd to import?
- How to delimit data csv for data import?
- How to solve errors while importing data
- Import and manage your Reagent & Supplies V5.3 and above
- Import your data (5.3 version and above)
- Import your data (v6.0)
- Import your samples and associated storage in 3 steps
- Importer ma BDD EndNote dans LabCollector (FR)
- What is a CSV file?
- What are the default fields values while importing data? v6.0
-
- How do you use versioning? v5.31 and below
- How do you use versioning? v5.4 and above
- How to manage users (v5.31 and below)
- How to manage users (v5.4 and above)
- How to use AD or LDAP for login authentication?
- What are group policies and how to use them?
- What are group policies and how to use them? v5.4 and above
- What are group policies and how to use them? v6.0
- What are user level permissions?
-
-
-
-
- How Do I Add Samples to a Specific Freezer, Shelf or Other Part of the Storage System?
- How do I get out samples from a specific freezer?
- How do I print box maps?
- How do I print storage records
- How to create box models for storage?
- How to create boxes/drawers/racks in storage equipment?
- How to replicate and duplicate boxes in storage?
- How to set up storage in LabCollector?
- How to store and manage straws? (EN/FR)
- Manage storage for Reagent & Supplies module
- How to organize Storage Browser?
-
- Barcode label generation and printing
- Barcode Printer Connection Time Out
- Compatible Label printers
- How can I configure my barcode scanner AGB-SC1 CCD?
- How can I configure my barcode scanner HR200C ?
- How do I configure FluidX to support ScanServer?
- How do I print barcode labels?
- How do I print box maps?
- How do I print records?
- How do I print risk and safety data information?
- How do I print storage records
- How to best configure your PDA N5000 for LabCollector use
- How to connect USB printer to LabCollector?
- How to print labels on HTTPS environment?
- How to configure printer with LabCollector?
- Label network printers and roll types
- Show all articles ( 1 ) Collapse Articles
-
- FDA CFR21 part 11 product checklist
- How do I use a Read-only field?
- How do you use versioning? v5.31 and below
- How do you use versioning? v5.4 and above
- ISO 17025 compliancy requirements
- Should I lock, archive or delete records?
- What are the FDA requirements for software to comply with GxP guidelines?
- What is in the Compliancy Pack?
-
-
-
- Apache Server/Web server doesn't run on Windows 10
- Clean the apache log manually to improve the speed.
- Clean the logs manually to improve the speed.
- ERROR in log: AH00052: child pid 3461 exit signal Segmentation fault (11)
- ERROR: Warning: mysql_connect(): Client does not support authentication protocol requested by server (…)
- How to make Java applets work again after upgrading to Java 7U51+?
- How to restore overwritten documents
- I have the message "Failed to connect to mySQL server. No Database found for this lab account". What can I do?
- My LabCollector or Add-on is very slow. Why and how to fix it?
- Unknown column “auto_name_mode” in “field list”: The error is occurring when I want to adjust existing records, make new records or import data. What can I do?
- URL issue
- When I add records or any values I have this message: "incorrect integer value: for column 'count' at row 1"
- Can the database be separated from the system on which labcollector is installed?
- Clean the apache log manually to improve the speed.
- Give access to LabCollector to collaborators outside your network
- How can I connect to LabCollector from another computer?
- How do I install Add-on modules?
- I have problems installing PHP and/or MySQL. Is there an alternative?
- Mysql Server memory usage optimization
- PHP extensions needed
- Rack scanners installation and connection with ScanServer
- System Requirements - Hosted options (FR/ENG)
- What are PHP and MySQL? Do I need to have PHP & MySQL?
-
-
- Error loading big reports in LabCollector
- Fields with scroll bar don't work with Safari, what can I do?
- I can't manage to view box scheme in Safari, why?
- I get the error: "The program can't start because MSVCR110.dll is missing from your computer. Try reinstalling the program to fix this problem" when installing or updating LabCollector for Windows
- Issue in upload file: look at your PHP configuration
- Module search fails with 404 error or request too long
- When I want to import large files, nothing happens?
- Why do I have the error “MySQL server has gone away” on file upload?
-
-
-
- Articles coming soon
-
-
- Editing a file using File Connector
- How to download and Install File connector v2.2? (Labcollector v6.0 )
- How to install Fileconnector in Mac OS? (Labcollector v6.0 )
- How to use a specific software to open certain types of files in fileconnector? (Labcollector v6.0 )
- How to use Fileconnector in Mac OS?
-
Manage storage for Reagent & Supplies module
- Main
- MODULES
- Reagent & Supplies
- Manage storage for Reagent & Supplies module
LabCollector offers two options to manage reagent and supplies storage.
- Follow: Admin > Preferences > Reagent & Supplies and choose one storage option.
If you select the Simple storage option, follow Admin > Storage > Simple Reagent Storage and list your storage.
You will find your list when you create/edit a product record.
If you select the Main storage option, you have to define your storage. Follow: Admin > Storage > Manage storage.
- Add a new facility (optional, there is one by default)
- Add new storage equipment, and select Shelf as Equipment type.
- In Storage Browser (Tools), under your new equipment, add a new drawer + a new box. It’s not really a box as a tube box or a plate, only a view of a part of your shelf.
In the form, you need to name your box (1), then choose Shelf part as box type (2) and create or select a rack/shelf if you want (3), then SAVE.
Once created you can see your shelf in the cupboard.
- Under Reagent & Supplies module, add a product. In Storage Location, you will read Defined separately.
To define your storage location, save your record and add storage. Storage can be edited by storage owner and administrators.
In Storage Box Management, select your equipment and then your shelf.
You can also import storage in batch and associate reagents to storage following one of the following KB articles, depending on your LabCollector version – KB- Import your data (5.3 and above) or KB-import your samples (5.25 and below).
Only Secondary storage is available for Reagent & Supplies module.